EasyManua.ls Logo

Intermec EasyCoder C4 - D - Density Command Settings; Direct Thermal Printing

Intermec EasyCoder C4
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Intermec EasyCoder C4 Programmers Guide Ed. 3 113 113
Appendix 1
Direct Thermal Printing
Label/Tag Type Ribbon Type Rec. Density at Speed S = 2 Max. Speed
Duratherm II D10 S3
Duratherm II Tag D9 S1
Duratherm Lightning D9 S3
Duratherm IR D7 S3
Thermal Top D8 S3
Thermal Eco D8 S3
Thermal Top Board D11 S2
Thermal Eco Board D7 S2
Thermal IR D12 S3
Thermal Top High Speed D6 S3
D - Density Command Settings
Recommended density settings are identi ed in the following tables.
Further adjustments might be necessary depending on print speed,
bar code density, orientation, and ambient temperature/humidity
conditions.