Intermec EasyCoder C4 Programmers Guide Ed. 3 12 12
Chapter 3
At delivery, the printers are set up as follows.
The setup will be reset to default values if...
the printers rmware is upgraded using a rmware cartridge, or
the Feed key is pressed more than 3 seconds in the Dump Mode.
Some commands may also affect the values of other command,
for example if a configuration label is printed (see U and UP
commands), the print direction is reset to ZT, and if an R Reference
Point command is executed, the label width (see q command)
will be changed.
Parameter Command Default Setting
Density D 10
Character Set I 8 bits, code page 0, country code 001
Top of Form backup JB/JF Enabled
Media feed adjust j 136 dots (tear-off/straight-through)
Label Gap Sensor O Normal (blockage of light = label)
Label Taken Sensor O Disabled
Ribbon End Sensor O Enabled (not used in pure DT printers)
Char. substitution oR No substitution
Form Length Q Length 1218, gap 24
Label Width q 832 dots (full width)
Reference Point R X:000;Y000
Print Speed S 50 mm/sec. (2 inches/sec.)
Error Handling UN/US Disabled
Windows Mode W Disabled
Serial Port Y 9600 baud, no parity, 8 data bits, 1 stop bit
Print Direction Z ZT (Start printing at top of image buffer)