Intermec EasyCoder C4 Programmers Guide Ed. 3 90
Chapter 7 Commands
Description
This command is used to enable the printers status reporting feature.
Syntax
US
Remarks
Serial Port:
If an error occurs while using the serial port, the printer will send a NAK (ASCII 21
dec.), followed by the error number, back to the computer. If no error occur, the printer
will echo ACK (ASCII 06 dec.) after each P (print) command.
If out-of-media or out-of-ribbon occurs, the printer will send, through the serial port, a
-07 and Pnnn where nnn is the number of forms remaining to print.
Parallel Port:
While using the parallel port, the printer will print the error number and the
control lamp will go orange (error).
The default setting is off (also see UN).
Error Messages
Message Meaning
ERR01 Syntax Error
ERR02 Object exceeds image buffer border
ERR03 Data length error (for example EAN 13 is 12 or 13 bytes only)
ERR04 Insuf cient memory to store forms or graphics
ERR05 Memory con guration error
ERR06 RS-232 error
ERR07 Out of media and/or ribbon
ERR08 Form or PCX name duplicate
ERR09 Form or PCX not found
ERR16 No form was retrieved before ? was entered.
ERR50 Does not t in area speci ed
ERR51 Data length too long
HINT!
Tap the Feed key three times to resume printing after an error.
Example
US :Enables error reporting
US Enable Error Reporting

Table of Contents

Other manuals for Intermec EasyCoder C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder C4 and is the answer not in the manual?

Intermec EasyCoder C4 Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder C4
CategoryPrinter
LanguageEnglish

Related product manuals