Goodrive200 inverters Function codes
106
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modify
memory
1:Power loss memoryPLC record the running step
and frequency when power loss.
P10.02
Multi-step
speed 0
0.0%
P10.03
The running
time of step
0
0.0s
P10.04
Multi-step
speed 1
0.0%
P10.05
The running
time of step
1
0.0s
P10.06
Multi-step
speed 2
0.0%
P10.07
The running
time of step
2
0.0s
P10.08
Multi-step
speed 3
0.0%
P10.09
The running
time of step
3
0.0s
P10.10
Multi-step
speed 4
0.0%
P10.11
The running
time of step 4
0.0s
P10.12
Multi-step
speed 5
0.0%
P10.13
The running
time of step
5
0.0s
P10.14
Multi-step
speed 6
0.0%
P10.15
The running
time of step
6
100.0%
of the frequency setting corresponds to the
Max. Frequency P00.03.
When selecting simple PLC running,
set
P10.02~P10.33 to define the running frequency
and
direction of all steps.
Note: The symbol of multi-step
determines the
running direction of simple PLC. T
he negative value
means reverse rotation.
Multi-step speeds are in the range of --f
max
~f
max
and
it can be set continuously.
Goodrive200 series inverters can set 16 step
s
speed, selected by the combination of multi-step
terminals 1~4, corresponding to the speed 0
to
speed 15.
0.0s