Goodrive200 inverters Function codes
Name
Detailed instruction of parameters
Default
value
Current limit
action
selection
The
decreasing
ratio during
current limit
The actual increasing ratio is less
output frequency because of the big load during
t is necessary to take measures to
avoid overcurrent fault and the inverter trips.
D
uring the running of the inverter, this function will
detect the output current and compare it with the limit
it exceeds the level, the inverter
l run at stable frequency in ACC running, or the
inverter will derate to run during
running. If it exceeds the level continuously
output frequency will keep on decreasing to the
f the output current is detected to be
lower than the limit level, the inverter will accelerate
to run.
Setting range of P11.05:
0:current limit invalid
1:current limit valid
2:current limit is invalid during constant speed
Setting range of P11.06:50.0~200.0%
Setting range of P11.07:0.00~50.00Hz/s
10.00Hz/
s
◎
P11.08
he output current of the inverter or the motor is
he lasting time is beyond P11.10,