Goodrive200 inverters Function codes
Name
Detailed instruction of parameters
Default
value
the
motor/inverte
r
G
motor:15
0%
P11.09
Overload
pre-alarm
test level
Overload
pre-alarm
detection
time
overload pre-alarm will be output.
Setting range of P11.08:
Enable and define the overload pre-
inverter or the motor.
Setting range: 0x000~0x131
LED ones:
0:Overload pre-alarm of the motor, comply with th
rated current of the motor
1:Overload pre-alarm of the inverter, comply
rated current of the inverter
LED tens:
0:The
inverter continues to work after underload
inverter continues to work after underload
ter stops to run after overload
inverter continues to work after overload
alarm and the inverter stops to run after
he inverter stops when overloading or
underloading.
LED hundreds :
0:Detection all the time
1:Detection in constant running
1.0s ○