Goodrive200 inverters Installation guidelines
33
4.3.5 Terminals of control circuit
Fig 4-20 Terminals of control circuit
Terminal
name
Description
+10V
Local power supply +10V
AI1
AI2
AI3
1. Input range: AI1/AI2 voltage and current can be chose:
0~10V/0~20mAAI1 can be shifted by J1;
AI2 can be shifted by J2
AI3:-10V~+10V
2. Input impedance:voltage input: 20kΩ; current input: 500Ω
3. Resolution: the minimum one is 5mV when 10V corresponds to
50Hz
4. Deviation ±1%, 25
GND +10V reference null potential
AO1
AO2
1. Output range:0~10V or -20~20mA
2. The voltage or the current output is depended on the jumper
3. Deviation±1%,25