Goodrive200 inverters Function codes
47
restored.
4. For a better parameter protection, the inverter provides password protection to the
parameters. After setting the password (set P07.00 to any non-zero number), the system will
come into the state of password verification firstly after the user press PRG/ESC to come
into the function code editing state. And then “0.0.0.0.0.” will be displayed. Unless the user
input right password, they cannot enter into the system. For the factory setting parameter
zone, it needs correct factory password (remind that the users can not modify the factory
parameters by themselves, otherwise, if the parameter setting is incorrect, damage to the
inverter may occur). If the password protection is unlocked, the user can modify the
password freely and the inverter will work as the last setting one. When P07.00 is set to 0,
the password can be canceled. If P07.00 is not 0 during powering on, then the parameter is
protected by the password. When modify the parameters by serial communication, the
function of the password follows the above rules, too.
Functio
n code
Name
Detailed instruction of parameters
Default
value
P00 Group Basic function group
P00.00
2:V/F control (applying to AM)
S
uitable in cases where it does not need high control
accuracy, such as the load of fan and pump. One
inverter can drive multiple motors.
Note: AM-Asynchronous motor
2 ◎
P00.01
Select the run command channel of the inverter.
The control command of the inverter includes:
up, stop, forward, reverse, jogging and fault
channel(“LOCAL/REMOT” light off)
Carry out the command control by RUN, STOP/RST
on the keypad.
Set the multi-function key QUICK/JOG as
shifting function (P07.02=3) to change
the running direction; press RUN and STOP/RST
simultaneously in running state to make the inverter