Goodrive200 inverters Function codes
48
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modify
coast to stop.
1:T
erminal running command channel
(“LOCAL/REMOT” flickering)
Carry out the running command control by the
forward rotation, reverse rotation and forward
jogging and reverse jogging of the multi
-
function
terminals
2:C
ommunication running command channel
(“LOCAL/REMOT” on)
The running command is controlled by the upper
monitor via communication.
P00.02
Reserved
Reserved 0
P00.03
Max. output
frequency
This parameter is used to set the maximum output
frequency of the inverter. Users should pay atte
ntion
to this parameter because it is the foundation of the
frequency setting and the speed of acceleration and
deceleration.
Setting range: P00.04~400.00Hz
50.00Hz
P00.04
Upper limit of
the running
frequency
The upper limit of the running frequency is
the upper
limit of the output frequency of the inverter which is
lower than or equal to the maximum frequency.
Setting range:P00.05~P00.03 (
Max. output
frequency)
50.00Hz
P00.05
Lower limit of
the running
frequency
The lower limit of the running freq
uency is that of the
output frequency of the inverter.
The inverter runs at the lower limit frequency if the
set frequency is lower than the lower limit one.
Note: Max. output frequency ≥ Upper limit frequency
≥ Lower limit frequency
Setting range:0.00Hz~P00.04 (Upper
limit of the
running frequency)
0.00Hz