Goodrive200 inverters Function codes
97
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modify
arrival
detection
value
above range of the set frequency, the multi-
function
digital output terminal will output the signal of
“frequency arrival”
, see the diagram below for
detailed information:
The setting range:0.00Hz~P00.03
(the Max.
frequency)
P08.37
Energy
braking
enable
This parameter is used to control
the internal braking
unit.
0:Disable
1:Enable
Note: Only applied to internal braking unit.
0
220V
voltage:3
80.0V
400V
voltage:7
00.0V
P08.38
Threshold
voltage
After setting the original bus voltage
, adjust this
parameter to break the load appropriately. The
factory value changes with voltage level.
The setting range:200.0~2000.0V
660V
voltage:1
120.0V
P08.39
Cooling fan
running
mode
Set the operation mode of the cooling fan.
0:Rated running mode: after t
he rectifier receives
operation command or the detected temperature of
0