IPE300 series engineering VFD Basic operation guidelines
-79-
Setting
Function
Description
1
Set frequency
0Max. output frequency
2
Ramp reference frequency
0Max. output frequency
3
Rotational speed
0Synchronous speed corresponding to max.
output frequency
4
Output current (relative to the VFD)
0Twice the VFD rated current
5
Output current (relative to motor)
0Twice the motor rated current
6
Output voltage
01.5 times the VFD rated voltage
7
Output power
0Twice the rated power
8
Set torque
0Twice the motor rated current
9
Output torque
0Twice the motor rated current
10
AI1 input
010V/020mA
11
AI2 input
-10V10V
12
AI3 input
010V/020mA
13
High-speed pulse HDIA input
0.0050.00Hz
14
Value 1 set through Modbus
communication
-10001000, 1000 corresponding to 100.0%
15
Value 2 set through Modbus
communication
-10001000, 1000 corresponding to 100.0%
16
Value 1 set through
PROFIBUS/CANopen/DeviceNet
communication
-10001000, 1000 corresponding to 100.0%
17
Set value 2 of
PROFIBUS/CANopen/DeviceNet
communication
-10001000, 1000 corresponding to 100.0%
18
Value 1 set through Ethernet
communication
-10001000, 1000 corresponding to 100.0%
19
Value 2 set through Ethernet
communication
-10001000, 1000 corresponding to 100.0%
20
High-speed pulse HDIA input
0.0050.00Hz
21
Value 1 set through
EtherCAT/Profinet communication
-10001000, 1000 corresponding to 100.0%
22
Torque current (bipolar, 100%
corresponding to 10V)
0Twice the motor rated current
23
Exciting current (100%
corresponding to 10V)
0the motor rated current
24
Set frequency (bipolar)
0Max. output frequency
25
Ramp reference frequency (bipolar)
0Max. output frequency
26
Rotational speed (bipolar)
0Max. output frequency