Service functions and error messages
Page 139
Error message
Meaning of the error message
Measures
Main
index
Sub index
1 General error, parameterisation Cause: Parameter session active for > 8 hrs.
The safety module has thus terminated the
parameterisation session.
The error message is saved in the permanent
event memory.
Action: Terminate parameterisation session within 8
hrs.
If necessary, start a new parameterisation
session and continue.
4 Buffer, internal communication Cause: Communication connection faulty.
Timeout / data error / incorrect sequence (packet
counter) in data transmission between the basic
device and safety module.
Too much data traffic, new requests are being
sent to safety module before old ones have been
responded to.
Action: Check communication interfaces, wiring,
screening, etc.
Check whether other devices have read access to
the servo drive and safety module during a
parameterisation session - this may overload the
communication connection.
Check whether the firmware versions of the
safety module and basic device and the versions
of the item Motion Soft® and SafetyTool are
compatible.
5 Communication module - basic device Cause: Packet counter error during transmission µC1
µC2
Checksum error during transmission µC1
µC2.