Service functions and error messages
Page 141
Meaning of the error message
Action:
This is an internal error in the module that should
not occur during operation.
Check the operating conditions (temperature, air
humidity, condensation).
Check the EMC wiring as
design; are there any external interference
sources?
Safety module may be faulty – is error eliminated
after replacing the module?
Check whether new firmware for the servo drive
or a new version of the safety module is available
from the manufacturer.
59 1 FSM: Fail-safe mode supply/safe pulse
inhibitor
Cause: Internal error in module in failsafe supply circuit
section or in the driver supply for the upper and
lower switches.
Action: Module faulty, replace.
2 FSM: Logic failure / intermediate circuit Cause: Reference voltage 2.5 V outside tolerance.
Logic supply overvoltage +24 V detected.
Action: Module faulty, replace.
3 FSM: Error internal power supply Cause: Voltage (internal 3.3 V, 5 V, ADU reference)
outside the permissible range.
Action: Module faulty, replace.
4 FSM: Error management, too many Cause: Too many errors have occurred simultaneously.