79
X-Series Waterblast Unit
6. Remove the journal bearing from the rod
cap and discard (Figure 158).
7. To access the inner journal bearing (Fig-
ure 159), push the connecting rod away
from the crankshaft. Slide the bearing
from the rod.
Inspection
1. Wipe the excess oil from the end cap
bearings.
2. Install a small strip of plasti-gauge onto
the end cap bearing (Figure 160).
3. Position the end cap with capscrews back
onto the matching connecting rod.
4. Screw in the capscrews by hand and then
tighten to the proper torque:
3000 Series Pumps: 45 ft.lb (61 N·m)
3600/4200 Series Pumps: 80 ft.lb (108
N·m)
5. Remove the end cap.
Figure 158: Bearing Removal.
Rod Cap
Journal Bearing
Figure 159: Inner Bearing Removal.
Connecting Rod
Journal Bearing
Crankshaft
Figure 160: Plasti-Gauge Installation.
Plasti-Gauge