Chapter 4 ADJUST MENU SETTINGS
4.11 MAINTENANCE
4-74
Motor Rotating Time
Initializes the scanner motor rotating time.
Initialize the motor rotating time as shown below when motor is replaced.
1 Open Scanner Time Clear - Motor Time Clear .
Yes : Clears the motor rotating time.
No : Does not clear.
When "Yes" is selected,
the motor rotating time stored in the scanner internal control circuit is initialized to
"0".
Scanner to Display Unit
Save the following scanner time data stored in the scanner into the display unit.
Scanner Running Time
Scanner Transmit Time
Motor Rotating Time
When replacing the scanner internal control circuit, perform the procedure below to
inherit scanner time data.
1. Save the scanner time data.
2. Replace the scanner internal control circuit
3. Restore the scanner time data.
1 Open Maintenance - Scanner to Display Unit .
Yes : Transfers the scanner time data to the display unit.
No : Does not transfer.