Loading...
Error
code
Description of error Cause Item to be checked
E965 Pitch motor
temperature error
In the case the pitch motor is applied
with an excessive load.
Check whether the pitch motor runs
smoothly.
E966 Feed driving motor
temperature error
In the case the feed driving motor is
applied with an excessive load.
Check whether the feed driving motor
runs smoothly.
E971 Pitch motor IPM
overcurrent
protection
Pitch motor maloperation.
E972 Pitch motor overload In the case the pitch motor is applied
with an excessive load.
Check whether the pitch motor runs
smoothly.
E973 Feed driving motor
IPM overcurrent
protection
Feed driving motor maloperation.
E974 Feed driving motor
overload
In the case the feed driving motor is
applied with an excessive load.
Check whether the feed driving motor
runs smoothly.
E975 Presser motor
IPM over-current
protection
Presser motor maloperation.
E976 Presser motor
overload
In the case the presser motor is applied
with an excessive load.
Check whether the presser motor
runs smoothly.
E977 CPU fault In the case of a program fault.
E978 Network
communication fault
In the case the data received from the
network is damaged.
E985 Return-to-origin
error of pitch motor
or feed driving motor
In the case the pitch motor has failed to
return to its origin.
In the case the feed driving motor has
failed to return to its origin.
Check whether the origin of the pitch
motor has been adjusted properly.
Check whether the origin of the feed
driving motor has been adjusted
properly.
– 121 –