Adjustment Procedure
Results of Improper Adjustment
4) Cleaning of the oil lter
Clean the oil lter ❶ periodically (approximately once every three
months).
1. Let the sewing machine fall down.
2. Remove the pipe stop ❶ and then the thread waste attached to
the oil lter ❷.
* Be careful that a lubrication pipe and so on are not damaged at
the time of maintenance of a lter.
◦ If there is clogging in the oil lter
❶, smooth lubrication cannot be
maintained from the lubrication
hole.
– 19 –