– 97 –
No. Item Setting range Edit unit
Counter motion selection
--- ---
Sewing counter No. of pcs. counter Bobbin counter
Height of eight of presser at the time
of 2 step stroke
(Control by motor)
50 to 90
(Control by air)
10 to 300
1
Buzzer sound can be prohibited.
--- ---
Without buzzer sound Panel operating sound
Panel operating sound + error
Number of stitches
of thread clamp release is set.
1 to 7 1
Clamping timing
of thread clamp can be delayed.
10 to 0 1
Thread clamp control can be prohibited.
--- ---
Normal
Prohibited
Feed motion timing is selected.
Set the timing in “–” direction when stitch is not
well-tightened.
8 to 16 1
State of the presser after end of sewing is selected.
--- ---
Presser goes up
after moving at
start of sewing.
Presser goes up
immediately after
end of sewing.
Presser goes up by pedal
operation after moving at
start of sewing.
Presser lifting motion at the end of sewing can be set.
--- ---
With presser up
Without presser up
Origin retrieval can be performed every time after end of
sewing (other than combination sewing)
--- ---
Without origin retrieval With origin retrieval
Origin retrieval in combination sewing can be set.
--- ---
Without origin
retrieval
Every time 1
pattern is nished.
Every time 1 cycle is
nished.
State of presser when sewing machine stops by temporary
stop command can be selected.
--- ---
Presser rise.
Presser rise with
presser switch.