CHAPTER 19
Maintaining Components
Required Tools and Parts for Maintaining the SRX320 Services Gateway Hardware
Components on page 85
Routine Maintenance Procedures for the SRX320 Services Gateway on page 85
Maintaining the SRX320 Services Gateway Cooling System Components on page 86
Maintaining the SRX320 Services Gateway Power Supply on page 86
Required Tools and Parts for Maintaining the SRX320 Services Gateway Hardware
Components
The following tools and parts are required to maintain the hardware components of the
services gateway:
Electrostatic bag or antistatic mat
Electrostatic discharge (ESD) grounding wrist strap
Flat-blade screw-blade screwdriver, approximately 1/8 in. (3 mm)
Phillips (+) screwdrivers, numbers 1 and 2
Related
Documentation
Routine Maintenance Procedures for the SRX320 Services Gateway on page 85
Maintaining the SRX320 Services Gateway Cooling System Components on page 86
Maintaining the SRX320 Services Gateway Power Supply on page 86
Routine Maintenance Procedures for the SRX320 Services Gateway
For optimum performance of the services gateway, perform the following preventive
maintenance procedures regularly:
Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the device and into the air intake vents.
Check the status LEDs on the front panel of the services gateway and on the
Mini-Physical Interface Module (Mini-PIM) that you are using.