1 Quick Reference
20 Keysight N6700 User’s Guide
[SOURce:]VOLTage (continued)
[:IMMediate][:AMPLitude] <NRf+>, (@chanlist)
Sets the positive voltage limit (only on N678xA SMU)
:COUPle <Bool>, (@chanlist)
Sets the voltage limit tracking state (only on N6784A)
[:IMMediate][:AMPLitude] <NRf+>, (@chanlist)
Sets the negative voltage limit (only on N6784A)
:MODE FIXed | STEP | LIST, (@chanlist)
Sets the voltage trigger mode
[:LEVel] <NRf+>, (@chanlist)
Sets the over-voltage protection level
:DELay[:TIME] <NRf+>, (@chanlist)
Sets the over-voltage protection delay (only on N6783A)
[:POSitive][:LEVel] <NRf+>, (@chanlist)
Sets the positive remote OV protection level (only on N678xA SMU)
:NEGative[:LEVel] <NRf+>, (@chanlist)
Sets the negative remote OV protection level (only on N6784A)
(Tracking commands only on Option J01)
[:STATe] <Bool>, (@chanlist)
Enables/disables tracking OVP
:OFFSet <NRf+>, (@chanlist)
Sets the tracking OVP offset
:RANGe <NRf+>, (@chanlist)
Sets the output voltage range
[:IMMediate] <NRf+> | INFinity, (@chanlist)
Sets the output voltage slew rate
:MAXimum <Bool>, (@chanlist)
Enables/disables the maximum slew rate override
Returns the value of the operation event register
Returns the value of the operation condition register
:ENABle <NRf>, (@chanlist)
Enables specific bits in the Event register
:NTRansition <NRf>, (@chanlist)
Sets the Negative transition filter
:PTRansition <NRf>, (@chanlist)
Sets the Positive transition filter
Presets all enable and transition registers to power-on
Returns the value of the questionable event register
Returns the value of the questionable condition register
:ENABle <NRf>, (@chanlist)
Enables specific bits in the Event register
:NTRansition <NRf>, (@chanlist)
Sets the Negative transition filter
:PTRansition <NRf>, (@chanlist)
Sets the Positive transition filter
Returns the number of output channels in a mainframe
Returns the model number of the selected channel
Returns the option installed in the selected channel
Returns the serial number of the selected channel
:RLSTate LOCal | REMote | RWLock
Specifies the Remote/Local state of the instrument
Returns the control connection port number
Returns the error number and error string
(Group commands do NOT apply to N678xA SMU)
Returns the groups that have been defined
Group multiple channels to create a single output
Removes the specified channel from a group
Resets the front panel lock password to zero
Returns the unit to its power-on state
Returns the SCPI version number
(Acquire commands only on N676xA, N678xA SMU and Option 054)
Triggers the measurement immediately
[:LEVel] <NRf>, (@chanlist)
Sets the current trigger level
:SLOPe POSitive | NEGative, (@chanlist)
Sets the current trigger slope