Used to smooth the input analog signals.
Filter frequency: f=4000/(2π*
Analog1_Filter)
Time Constant (T) = Analog2_Filter/4000
(S)
Sets dead zone data for external analog
signal 2
Sets offset data for external analog signal 2
Selects analog-speed channels
0: Invalid analog channel
1: Valid analog channel 1 (AIN1)
2: Valid analog channel 2 (AIN2)
Valid mode -3 and mode 3
Sets the proportion between analog signals
and output speed
0: No control
1: Max torque that Ain1 can control
2: Max torque that Ain2 can control
Indicates the max torque factor for analog
signal control
7.2.3 Analog Signal Processing
Fig. 7-6 Analog signal processing
Electrical control on internal variables is available only after ADC conversion and offset of external analog
signals, and judgment of dead zone signals.
For offset processing, see the left part in Fig. 7-6; for dead zone processing, see the right part in Fig. 7-6.
Mathematical equation for offset processing:
shiftexternalernal
UUU
int