5.2 Description of Parameters
Group F000 represents an instruction group, and the parameters in this group cannot be saved.
The address d4.00 is used to save the motor parameters set for Group F004. Note that this group of
parameters must be set when customers choose third-party motors, but these parameters need not to be set for
the motors delivered and configured by our company. d2.00, d3.00 and d.5.00 represent the same address, and
are used to save all setup parameters except those of motors (Group F001/F002/F003/F004/F005). Three
numeric objects (d2.00/d3.00/d5.00) are developed to facilitate customers.
Parameter List: Group F000 (To Set Driver Instructions)
0.004 (-4): Pulse control mode, including
pulse direction (P/D) and double pulse
(CW/CCW) modes. 0.003 (-3):
instantaneous speed mode
0001 (1): Internal position control mode
0003 (3): Speed mode with
acceleration/deceleration
0004 (4): Torque mode
Note: Only applied in the working mode
where no external signals control the
driver.
000.0: Releases the motor
000.1: Locks the motor
001.0: Clears errors
Note: Only applied in the situation where
enabling a driver or wrong resetting is
not controlled by external signals. After
the wrong reset of the driver, the motor
must be enabled again.
Sets the motor’s target rotation speed
when the driver works in the ―-3‖ or ―3‖
mode and the address d3.28 is set to 0
(without external analog control).
Sets input torque instructions (current
instructions) when the driver works in
the ―4‖ mode and the address d3.30 is
set to 0 (without external analog
control).
Sets the velocity loop bandwidth. The
unit is Hz.
This variable can only be set after auto
tuning is performed properly; otherwise