Fault Cause Remedy
The LED on the
evaporator lights
up, the Cloud
symbol flashes in
the controller
display
(SANARIUM S).
There is no water. Open the angle valve on the evaporator.
' See page 36/37.
There is no steam
escaping
(SANARIUM S).
The angle valve on the
evaporator is closed.
Open the angle valve on the evaporator.
' See page 36/37.
The evaporator is not
switched on.
Switch on the evaporator.
' See page 36/37.
Evaporator fault. ' See page 60.
The fuse in the cable has
tripped.
The inlet pump is faulty. ' Contact Klafs service engineers.
Yellow or red LED
on the evaporator
lights up
(SANARIUM S).
The evaporator must be
serviced.
Service the evaporator.
' See page 60.
The steam cylinder is worn.
The inlet pump is faulty. ' Contact Klafs service engineers.
The drain pump is faulty.
. Only with
evaporator S with
Birmingham scent
dispenser:
Scent is not being
released
(SANARIUM S).
The scent container is empty. Replace the scent container.
' See page 61.
The scent pump does not
work or is defective.
' Contact Klafs service engineers.
The feed hose in the pump is
defective.
' See Servicing Instructions 18029,
18033, 18040.
The scent line is clogged or
defective.
Check the scent line from the pump to the
evaporator tube.
Replace the defective scent line.
The scent inlet at the T-piece
to the evaporator tube is
clogged.
Check the scent line to the evaporator tube.
Clean the scent inlet at the T-piece to the
evaporator tube.
' See page 61.