SANARIUM B, S
PAGE 55
50701206/02.18
11. If something does not work
11.2. Other possible errors
Continued
RemedyCauseFault
The controller
cannot be started
or operated.
The controller is controlled by
TOUCHCONTROL.
The operating panel is
locked.
Turn off TOUCHCONTROL.
. After approx. 5 minutes,
TOUCHCONTROL activates the
controller.
Disconnect the data lead between the
TOUCHCONTROL and the controller.
The controller
cannot be
operated.
The touchscreen lock symbol
appears on the touchscreen.
The touchscreen lock is
switched on.
Switch the touchscreen lock off.
' See page 48.
The sauna heater
does not heat up
(when controlled
via
TOUCHCONTROL
or Central
Building Control
CBC).
The additional option (key)
appears in the display for
30 minutes.
. Remove flammable objects from the
sauna heater.
Press the key switch on the sauna cabin for
one second within 30 minutes of pressing
Start on TOUCHCONTROL or CBC.
The additional option (key)
does not appear in the
display.
Output from sauna cabin
heater not requested by
CBC.
The 30-minute waiting time
has elapsed.
Request output from the sauna cabin heater
via CBC.
Changes to temperature
settings have not been
applied.
Press the key switch on the sauna cabin
within 30 minutes of changing the settings.
Fan cannot be
adjusted.
The Climate Manager is
connected.
. The air flow rate is regulated by the
Climate Manager.
The InfraPLUS
heaters will not
switch on.
The incorrect bathing mode
has been selected.
Select InfraPLUS mode.
' See page 27.
The temperature in the cabin
is greater than 50 °C.
Open the cabin door and allow the
temperature to fall.
The InfraPLUS heater is not
being supplied with power.
Check the fuse in the power supply.
Switch the power supply on.
Continued on the next page