11. If something does not work
11.2. Other possible errors
Continued
RemedyCauseFault
AQUAVIVA does
not start.
The mains switch on the
AQUAVIVA controller is
switched off.
Switch on the mains switch at the
AQUAVIVA controller.
The fuse in the feed line to
the AQUAVIVA controller has
blown.
Replace or reset the fuse.
The CAN line is interrupted. Check the CAN line.
The expander circuit board is
defective or not plugged in.
Check the expander circuit board and
replace if necessary.
Starry Sky cannot
be switched on.
The mains switch on the
Starry Sky controller is
switched off.
Switch on the mains switch on the Starry Sky
controller.
The fuse in the feed line to
the Starry Sky controller has
blown.
Replace or reset the fuse.
The CAN line is interrupted. Check the CAN line.
The expander circuit board is
defective or not plugged in.
Check the expander circuit board and
replace if necessary.
The coloured light
cannot be
switched on.
The fuse in the feed line to
the coloured light controller
has blown.
Replace or reset the fuse.
The CAN line is interrupted. Check the CAN line.
The reading light
cannot be
switched on.
The bulb in the reading light
is defective.
Replace the bulb in the reading light.
Replace with a bulb of the same wattage.
The electrical connection
between the reading light
and IMES-1 is interrupted.
Check and secure the electrical connection.
Remote power-on
symbol.
The controller will not switch
on.
On service menu item 20 KEY, change the
setting to [2] Remote.
' See Servicing Instructions 18029,
18033, 18040.