90 °C
60 °C
40 °C
Page 95 / 96
12.8. Fero S - Decalcifying the evaporator
4
1
3
2
3
Fero S - Rinsing
5. Close the drain valve (4).
6. Fill the evaporator's filling unit (2)
with fresh water.
7. Place the filler can (3) under the
drain. Open the drain valve (4).
8. Close the drain valve (4) again
after draining the evaporator.
9. Repeat the rinsing procedure two
or three times.
10. Use the aroma fork to place the
cover plate (1) on the sauna heater
water tank together with the aroma
cup.
SONSTIGES
Settings
Activation ALEXA
Language
Water hardness
Servicemenu
Time
ASC PIN
Pairing Bluetooth
Lock control
Back
Decalcification done
5
Resetting error 92 on the control panel
D The final drying phase must have
finished.
11. Carry out decalcification.
12. In standby mode, clear the error
message by pressing symbol (5).
D The message "Error 92" for
evaporator maintenance will be
reset.