EasyManua.ls Logo

Kleemann GENIUS20 - Page 207

Default Icon
233 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
207
MA06-03-1-01
Menu
Error code : 70
Reset
800+Ok and note the instructions for retracting the aprons
Short text
Apron magnet Door 1!
Long text
Apron input is bridged!
Description
Should the installation be equipped with a holding magnet (HM) for aprons, then an input about the HM’s
retraction will be expected when issuing the output for the HM.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- hinged apron folded out even though the HM is supplied with current.
- wiring not correct
- defective input
Remedy
- retract hinged apron
- in case of automatic folding, please note the operating procedures
If the input should be defective it can be parameterized to another available I/O any time.
Error code : 71
Reset
800+Ok and note the instructions for retracting the aprons
Short text
Apron not activ in normal mode at door 1, because of S chain!
Long text
Apron not activ in normal mode at door 1, because of S chain!
Description
If the controller recognizes the S6 input to open during travel, the holding magnet for the hinged apron
deactivates.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- S6 has been opened during travel
Remedy
Error code : 72
Reset
800+Ok and note the instructions for retracting the aprons
Short text
Apron input door 2!
Long text
Apron input active in normal mode at door 2!
Description
Under normal operation, the controller expects to receive input about the hinged aprion being retracted.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- hinged apron folded out
- wiring not correct
defective input
Remedy
- retract hinged apron
- in case of automatic folding, please note the operating procedures
If the input should be defective it can be parameterized to another available I/O any time.
Error code : 73
Reset
800+Ok and note the instructions for retracting the aprons
Short text
Apron magnet Door 2!
Long text
Apron magnet output door 2 active but no effect on input!
Description
Should the installation be equipped with a holding magnet (HM) for aprons, then an input about the HM’s
retraction will be expected when issuing the output for the HM.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- hinged apron folded out even though the HM is supplied with current.
- wiring not correct
- defective input