208
MA06-03-1-01
Menu
Remedy
- retract hinged apron
- in case of automatic folding, please note the operating procedures
If the input should be defective it can be parameterized to another available I/O any time.
Error code : 74
Reset
800+Ok and note the instructions for retracting the aprons
Short text
Apron door 2 S chain!
Long text
Apron activ in normal mode at door 2, because of S chain!
Description
If the controller recognizes the S6 input to open during travel, the holding magnet for the hinged apron
deactivates.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- S6 has been opened during travel
Remedy
Error Code: 75
Reset
800 + Ok
Short text
Car door is bridged
Long text
Car door is bridged
Description
Notification that the safety circuit S4 is bridged. Prerequisite for this is that monitoring is activated in the
lift attendant menu.
Reaction
General
The control switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- Bridge at S4
Remedy
- Check wiring
Error Code: 76
Reset
800 + Ok
Short text
Landing door is bridged
Long text
Landing door is bridged
Description
Notification that the safety circuit S6 is bridged. Prerequisite for this is that monitoring is activated in the
lift attendant menu.
Reaction
General
The control switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- Bridge at S6
Remedy
- Check wiring
Error code : 77
Reset
Automatic
Short text
Small Pit room DOWN!
Long text
small Pit room to move down in inspection!
Description
Notification that the inspection limit switch which is simulated by the software has been reached during
downward travel.
Reaction
General
Rope
Hydraulic
Causes
- Simulated limit switch has been reached
Remedy
- Leave the limit switch by travelling up