- retract hinged apron
- in case of automatic folding, please note the operating procedures
If the input should be defective it can be parameterized to another available I/O any time.
800+Ok and note the instructions for retracting the aprons
Apron activ in normal mode at door 2, because of S chain!
If the controller recognizes the S6 input to open during travel, the holding magnet for the hinged apron
deactivates.
The controller switches into “out-of-order” mode.
- S6 has been opened during travel
Notification that the safety circuit S4 is bridged. Prerequisite for this is that monitoring is activated in the
lift attendant menu.
The control switches into “out-of-order” mode.
Notification that the safety circuit S6 is bridged. Prerequisite for this is that monitoring is activated in the
lift attendant menu.
The control switches into “out-of-order” mode.
small Pit room to move down in inspection!
Notification that the inspection limit switch which is simulated by the software has been reached during
downward travel.
- Simulated limit switch has been reached
- Leave the limit switch by travelling up
- check parameters