209
MA06-03-1-01
Menu
Error code : 78
Reset
Automatic
Short text
Apron distance!
Long text
Because of apron distance not possible to move down more!
Description
The min. distance from the shaft pit which is allowed to be reached with an out-folded apron has been
reached during downward travel.
Reaction
General
The controller initiates an emergency stop
Rope
Hydraulic
Causes
- limit has been reached
- parameters not set correctly
Remedy
- retract the hinged apron, retract the telescopic apron
- check parameters Menu -> Parameter -> Input/Output -> In car -> Auto hinged apron ->
Dist.limit to drive
Error code : 79
Reset
800 + Ok / Recall / Reset
Short text
Brake 3 not opened!
Long text
Brake 3 not opened!
Description
3 sec. after the beginning of travel, the controller checks whether the brakes are released; that is in case
of an error the input Brake3 is still applied.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- brake activation does not function properly (refer to wiring diagram)
- brake shoe contact is not set up correctly
- wiring not correct
- Brake MCB (FBR)
- defective input
Remedy
- see causes
- check input on the status page (BR3)
If the input should be defective it can be parameterized to another available I/O any time.
Error code : 80
Reset
800 + Ok / Recall / Reset
Short text
Brake 3 not closed!
Long text
Brake 3 not closed!
Description
3 sec. after the termination of travel, the controller checks whether the brakes are closed; that is in case
of an error the input Brake3 is not applied.
Reaction
General
The controller switches into “out-of-order” mode.
Rope
Hydraulic
Causes
- brake activation does not function properly (refer to wiring diagram)
- brake shoe contact is not set up correctly
- wiring not coorect
- defective input
Remedy
- see causes
- check input on the status page (BR3)
If the input should be defective it can be parameterized to another available I/O any time.