36
MA06-03-1-01
Menu
[Direct access: CMD -> 7026 ->7008]
Parameter
[Direct access]
Description
Default
value
Value
Range
Number of cars in group
Selection of the number of group cars.
0-16
Number in group
Selection of car/lift number in the group. Each
car is given a number based on a consecutive
numbering. The car number is sent in the group
log, which serves to inform the other cars about
the status.
1-16
T:Car out of group
Time in seconds after which this lift leaves the
group, i.e. to release the landing in which this car
is positioned for other group lifts (e.g. blocking
due to hinged doors which are open for a longer
time).
60
0-9999 s
Open all doors by la.call
Select whether all lifts in a particular landing are
to open their doors in case of a landing call.
NO
YES/NO
O: Bus switchover
When activating the push buttons, one landing-
bus may be used by two group lifts.
If one of the lifts falls out of operation, the bus
and supply voltage of the adjoining lift are taken
over by a relay which is activated via the closed
output.