51
MA06-03-1-01
Menu
[Direct access: CMD -> 7030 -> 7036]
Parameter
[Direct access]
Description
Default
value
Value Range
Stopping distance Up
v0 (mm)
Distance provided to the drive for stopping
in upward direction. If the drive (inverter)
requires 3 cm from creeping velocity to
standstill, the stopping distance must be
set to 30.
5
0-9999 mm
Stopp. dist. Down v0
(mm)
Distance provided to the drive for stopping
in downward direction. If the drive
(inverter) requires 3 cm from creeping
velocity to standstill, the stopping distance
must be set to 30.
5
0-9999 mm
Stop. distance up vn
(mm)
Distance provided to the drive for stopping
in upward direction in relevelling speed.
5
0-9999 mm
Stop.dist. down vn
(mm)
Distance provided to the drive for stopping
in downward direction in relevelling speed.
5
0-9999 mm
Deceleration vZ1 (mm)
Deceleration distance (in millimetres) for
intermediate speed 1 (vZ1). Necessary
precondition is the utilization of
intermediate speed 1 on page 034
(speeds).
500
0-9999 mm
Deceleration vZ2 (mm)
Deceleration distance (in millimetres) for
intermediate speed 2 (vZ2).
Necessary precondition is the utilization of
intermediate speed 2 on page 034
(speeds).
1200
0-9999 mm