EasyManuals Logo

Kleemann GENIUS20 User Manual

Default Icon
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
52
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value Range
Deceleration vZ3 (mm)
Deceleration distance (in millimetres) for
intermediate speed 3 (vZ3).
Necessary precondition is the utilization of
intermediate speed 3 on page 034
(speeds).
0
0-9999 mm
Decel. Up Vrated (mm)
Switchover point to creeping velocity in
upwards travel. Distance to destination
(millimetres) in which the creeping velocity
is to be reached in upward direction.
2000
0-9999 mm
Decel. Down Vrated
(mm)
Switchover point to creeping velocity in
downwards travel. Distance to destination
(millimetres) in which the creeping velocity
is to be reached.
2000
0-9999 mm
Approach speed
(mm/s)
Definition of the car’s approach speed into
the zone in mm/s. When contemplating
the drive curve it can be seen that after
travelling with normal speed and the
deceleration interval, the approach speed
is used until standstill. The indication of
this speed value primarily serves to check
up on the drive curve.
100
0-9999
mm/s
Min. deceleration
(m/s2)
Definition of the minimum deceleration
after travelling with rated speed. If the set
deceleration value is too small, the lift car
cannot stop in time and thus an error
message is issued.
0
0-9999
mm/s
2
Test point = x mm
Test point distance (internal use).