EasyManuals Logo

Kleemann GENIUS20 User Manual

Default Icon
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
54
MA06-03-1-01
Menu
[Direct access: CMD -> 7031]
Parameter
[Direct access]
Description
Default
value
Value Range
Dir. depend. Call
cancel.
Selection whether landing calls are to be
cancelled direction-dependently.
YES
YES/NO
Distance delete calls
(mm)
Distance to target destination (in
millimetres) at which calls are deleted.
1200
0-9999mm
T: Blocking call (s)
Time for call acceptance blocking (in
seconds) when two buttons are
simultaneously pressed.
0
Landing calls selective
Selection whether landing calls are
selectively processed.
NO
YES/NO
Car calls selective
Selection whether car calls are selectively
processed.
NO
YES/NO
Car call has priority
Select whether the internal calls have
priority over the external calls.
This parameter is especially used at lifts
installed in places with public traffic and
correspondingly restricted areas, and a
zero-load monitoring is not practical.
If this parameter is activated, landing calls
are saved but not processed as long as a car
call is present. This prevents unauthorized
users in the car from accidentally entering
a restricted floor.
NO
YES/NO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kleemann GENIUS20 and is the answer not in the manual?

Kleemann GENIUS20 Specifications

General IconGeneral
BrandKleemann
ModelGENIUS20
CategoryController
LanguageEnglish