55
MA06-03-1-01
Menu
In order to approach with open/opening doors the following requirements must apply:
existence of a safety circuit (safety relays K5, K6, K7) on the Genius central electronic unit.
use of a selection system with 2 zone signals.
override of door switches in the zone.
[Direct access: CMD -> 7063]
Parameter
[Direct access]
Description
Default
value
Value Range
Distance (mm)
Distance to the landing at which the doors
are caused to open.
50 mm
0-9999 mm
Maximum Speed
(mm/s)
Maximum speed at which the doors are
caused to open.
300 mm
0-9999 mm