Parameter
[Direct access]
Query whether a safety light curtain is installed
as a replacement for the car doors.
The parameters of the submenu “Hinged doors 2” are exactly the same with the ones for the 1st door.
[Direct access: CMD -> 7083]
Parameter
[Direct access]
Definition of an output for the actuation of a
relay serving the reset of a safety light curtain
after a breakdown.
Definition of an input for the initiation of a reset
at the safety light curtain via a separate reset-
button.
Selection of a rolling text which is to be displayed
in the event of a breakdown or intermission at
the safety light curtain.
Query whether a reset of the safety light curtain
is to be permitted when issued via a landing call.
Ordinarily, a reset is only initiated via a car call
or reset button.
Output for a notification, e.g. acoustic signal,
indicating an intermission at the safety light
curtain.