EasyManua.ls Logo

Kleemann GENIUS20 - Page 62

Default Icon
233 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62
MA06-03-1-01
Menu
Parameter
[Direct access]
Description
Default
value
Value Range
Safety light curtain
Query whether a safety light curtain is installed
as a replacement for the car doors.
NO
YES/NO
The parameters of the submenu “Hinged doors 2” are exactly the same with the ones for the 1st door.
[Direct access: CMD -> 7083]
Parameter
[Direct access]
Description
Default
value
Value
Range
O:Reset light curtain
Definition of an output for the actuation of a
relay serving the reset of a safety light curtain
after a breakdown.
I:Reset light curtain
Definition of an input for the initiation of a reset
at the safety light curtain via a separate reset-
button.
Rolltext number
Selection of a rolling text which is to be displayed
in the event of a breakdown or intermission at
the safety light curtain.
0
1-10
Reset over landing call
Query whether a reset of the safety light curtain
is to be permitted when issued via a landing call.
Ordinarily, a reset is only initiated via a car call
or reset button.
NO
YES/NO
O:light curtain detect
Output for a notification, e.g. acoustic signal,
indicating an intermission at the safety light
curtain.