MV-6 - Protocol 3000 Commands
Command - W-LAYER
Command Type - Multiviewer
Command Name
Permission
Transparency
Set:
W-LAYER
End User
Public
Get
W-LAYER?
End User
Public
Description
Syntax
Set 1:
Set window overlay order
#W-LAYER win_num,value
Set 2:
Set all window overlay order
#W-LAYER0xFF,value1,value2, …,valueN
Get 1:
Get window overlay order
#W-LAYER?win_num
Get 2:
Get all window overlay order
#W-LAYER?0xFF
Response
Set 1/Get 1: ~ nn@W-LAYER win_num, value␍␊
Set 2/Get 2: ~ nn@W-LAYER0xFF,value1,value2,…valueN␍␊
Parameters
win_num - window number setting layer
value - overlay order number
Response Triggers
After execution, response is sent to the com port from which the Set/Get was received
After execution, response is sent to all com ports if W-LAYER was set by any other external control device
(button press, device menu and similar)
Notes
In case of overlays order list, number of expected layers is maximum number of windows in device
Command W-SRC
Command Type - Multiviewer
Command Name
Permission
Transparency
Set :
W-SRC
User
Public
Get
W-SRC?
User
Public
Description
Syntax
Set:
Set window source
#W-SRC win_num,src
Get:
Get window source
#W-SRC? win_num
Response
~ nn @W-SRC win_num,src ␍␊
Parameters
win_num - window number to set new source
src input source to connect to window (1… max input number)
Response Triggers
After execution, response is sent to the com port from which the Set/Get was received
After execution, response is sent to all com ports if W-SRC was set by any other external control device
(button press, device menu and similar)