Terminal – menus [Medium Plus/Comfort Plus Electronics] 9
Alarm messages 9.16
Supplement to Operating Instructions 150000773_00_en
BiG Pack 1270, BiG Pack 1270 XC, BiG Pack 1290, BiG Pack 1290 HDP, BiG Pack 1290 HDP XC, BiG Pack
1290 XC, BiG Pack 890, BiG Pack 890 XC
89
Error number Designation Icon
521104-5 Voltage group(UB5)
521105-5 Voltage group(UB6)
FMI 6: There is a short circuit or ground fault.
Error number Designation Icon
521100-6 Voltage group(UB1)
521101-6 Voltage group(UB2)
521102-6 Voltage group(UB3)
521103-6 Voltage group(UB4)
521104-6 Voltage group(UB5)
521105-6 Voltage group(UB6)
FMI 11: The cause of the error is unknown.
Error number Designation Remedy
521106-11 The supply voltage of the sensors could not
be activated.
9.16.1.5 Logical errors 522000 – 522099
Error number Possible cause Remedy
522000-7 During active lubrication no
lubrication flow was detected.
• Top up grease.
• Clean the central lubrication.
• Check the electrical system and
the pump.
522001-7 The flywheel brake is engaged and
the cardan shaft is rotating.
• Release the flywheel brake.
522002-7 The starting aid is active while the
flywheel brake is engaged.
522003-0 The slip of the tensioning belt on the
cutting rotor is too great.
• Remove the crop blockage.
• Set the sensor.
522004-0
The pressure on the belt drive for the
cutting rotor is too great.
• Check the hydraulics.
• Check the sensor and replace if
required.
522005-2 The cardan shaft rotates in "road
travel" mode.
• Switch off the PTO shaft.
• Switch the operating mode
522006-0
The cardan shaft is rotating more
quickly than permitted.
• Reduce cardan shaft speed.