14.7.20 Menu 15-1 “Sensor Test”
Pos: 45.28.102 /BA/I nfo-Center/ALLE Ter minals in einem - ISOBUS, Delta, BETA II (ab BJ 15/16)/ ALLE Terminals/Rundba llenpressen/Menü 15- 1 Sensortest_Bild_A LLE Terminals_Fortima @ 385\ mod_1444719472979 _78.docx @ 2759706 @ @ 1
IBT000049
IBT000230
OK
L
R
Fig. 126
Pos: 45.28.103 /BA/I nfo-Center/ALLE Ter minals in einem - ISOBUS, Delta, BETA II (ab BJ 15/16)/ ALLE Terminals/Übergrei fend über alle Maschine n/Menü 15-1 Sensortest_ Text_ALLE Terminals @ 384\mod_144438647930 5_78.docx @ 2757705 @ @ 1
Prerequisite
Menu “Settings” is called, refer to chapter Terminal - Menus, “Menu 15 ‘ISOBUS Settings’”.
• Select to open the menu.
The display shows menu 15-1 “Sensor Test”.
Selecting the sensor
Navigate through the displayed sensors using and and select the desired sensor.
The selected sensor is highlighted in grey and tested.
Setting values
In the upper section of the bar display, the minimum and maximum setting value with alive
sensor (metal in front of the sensor) is displayed. The current setting value is displayed under
the bar display.
The distance from the sensor to the metal must be set so that the bar is within the upper
marking in the alive state. Then check whether the bar is in non-alive state in the lower marked
area.