8 SHOCK ABSORBER, SWINGARM 48
201285-10
– Measure distance A between the floating piston and reservoir hole with the special
tool.
Depth micrometer (T107S) ( p. 219)
The floating piston is positioned all the way at the bottom.
200267-10
– When the vacuum pressure gauge reaches the specified value, turn the Oil reser-
voir control lever 5 to Equalize pressure.
Guideline
4 mbar
The pressure gauge rises to the specified value.
0 bar
200268-10
– When the pressure gauge reaches the specified value, turn the Damper control
lever 4 to Pressure.
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge rises to the specified value.
3 bar
200269-10
– When the pressure gauge reaches the specified value, turn the Damper 4 control
lever to Vacuum.
Guideline
3 bar
The pressure gauge falls to the specified value.
0 bar
200270-10
– When the pressure gauge reaches the specified value, turn the Oil reservoir 5 con-
trol lever to Vacuum.
Guideline
0 bar
The vacuum gauge falls to the specified value.
4 mbar
200267-10
– When the vacuum pressure gauge reaches the specified value, turn the Oil reser-
voir control lever 5 to Equalize Pressure.
Guideline
4 mbar
The pressure gauge falls to the specified value.
0 bar