KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021 Page - 103 -
1.) Interrupt If there is a fault in inverter, drive-orders and calls will be erased. If there is a new
call, the controller tries again to start.
2.) Block If there is a fault in inverter, drive-orders and calls will be erased. The controller is
blocked. Only a RESET-signal can turn on the controller.
3.) Block at 2.Fault If there are two faults in a series in inverter, drive-orders and calls will be
erased. The controller is blocked. Only a RESET-signal can turn on the controller.
4.) Block at 3.Fault If there are three faults in a series in the inverter, drive-orders and calls
will be erased. The controller is blocked. Only a RESET-signal can turn on the controller.
PARAMETER: COMMAND OUTPUT
With this parameter can be adjusted, as the expenditure for command takes place to the regulation.
Two variants are available:
1) With On and Off command (standart GOLIATH)
2) With release and a direction command (DIETZ)
Submenu Speeds ( Only with setting CANopen & FU )
This parameter can be used to set how the command output for regulation takes place. There are two
variants to choose from:
Parameter „Speed catching up Vn
Here you can set the speed Vn. Factory setting Vn: 00,123m/s“
Parameter „Speed inspection Vi1
Here, the speed is set Vi1. Factory setting Vi1: 00,123m/s“
Parameter „Speed inspection Vi2
Here, the speed is set Vi2. Factory setting Vi2: 00,123m/s“
Parameter „Speed return motion VR
Here the speed is set VR. Factory setting VR: 00,123m/s“
Parameter „Speed evacuation VE
Here the speed is set VE. Factory setting VE: 00,123m/s“
Parameter „Speed entrance V0
Here the speed is set V0. Factory setting V0: 00,123m/s“
Parameter „Speed Between V1
Here the speed is set V1. Factory setting: V1: 00,123m/s“
Parameter „Speed Between V2
Here the speed is set V2. Factory setting: V2: 00,123m/s“
Parameter „Speed end V3
Here the speed is set V3. Factory setting: V3: 00,123m/s“