1.6 DESCRIPTION OF TEMPERATURE MONITOR ZR
Product Controller for Elevators
Type Microprocessorsystem DAVID-2001/2005/613 – Main Unit ZR
The central unit ZR has an electronic circuit for the collection of the temperature
within the equipment. In the software the temperature threshold can for the cycle
non-repeat function of the plant can between 30 degrees Celsius and 100 degrees
Celius be adjusted.
During factory setting the temperature thresold was specified on 60 degrees Celsius.
Stopping the plant means an entry with a rope elevator into the next stop and/or with
a hydraulic elevator the execution of an emergency sinking in the lowest stop and re-
fusal of call acceptance to the switch gear cabinet temperature below the limit value
threshold sinks.