KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021 Page - 72 -
4.3 USB Interface 1, 2 & 3
The USB interface 1 (slave) is used for connection of a PC-based system for communicating with the
control computers. With the parameterization software or Flash software, the parameters in the control
system can be 613 DAVID changed.
The second and third USB port is reserved for USB devices that require a USB master. In the future,
here you can connect USB flash drives, USB modems, USB printers.
4.4 CANOpen Interface 1, 2 & 3
With the new processor system DAVID 613 there are on the central unit two CANopen interfaces and
on the car unit there is another one available.
In the future here can be CANOpen Komponeten as shaft copy systems, control devices, etc. connect.
4.5 WLAN / WiFi Transceiver
The processor system DAVID 613 has an access point for WLAN / WiFi. With smart phones and tab-
lets and the corresponding apps can be accessed on the parameters of the controller.
Communication with Apple devices such as iPhone and iPad is currently possible.