2.6 DESCRIPTION EXPANSION DEVICE ON THE CAR DAVID-ZG-24F
The expansion unit ZG-24F offers 24 additional inputs
and outputs. The ZG-24F is connected to the car cal-
culator FKR with a 10-pole flat-wire cable.
The input and output assignment is freely selectable.
Up to 5 additional groups of type ZG24F can be oper-
ated in a control system D613.
Adress switching on the Expansion Unit:
KW-Nr. 1100060
On the last ZG24F module in the chain, the Dipp-4 switch is set to ON and serves as termina-
On each ZG24F, there are 2 34-
pin flat connectors to which an EIT module can be connected.
This allows the call lines to be connected to the internal control at 64 stops.
Activation takes place:
1.) Insert the module on the FKR computer
2.) By activating in the B21 menu:
Three settings are selectable:
A. Without FKR + EIT
B. With FKR + EIT (IC .. IE) -> Standard without ZG24F
C. With FKR + EIT (IC .. IU) -> With ZG24F Expansion Units!
Terminal -Description Expansion Unit DAVID-ZG-24F