DAVID-D613-V125-E 13.04.2021 Page - 30 -
2.6 DESCRIPTION EXPANSION DEVICE ON THE CAR DAVID-ZG-24F
The expansion unit ZG-24F offers 24 additional inputs
and outputs. The ZG-24F is connected to the car cal-
culator FKR with a 10-pole flat-wire cable.
The input and output assignment is freely selectable.
Up to 5 additional groups of type ZG24F can be oper-
ated in a control system D613.
Adress switching on the Expansion Unit:
DIPP-0
DIPP-1
DIPP-3
1. ZG24F
OFF
OFF
OFF
2. ZG24F
ON
OFF
OFF
3. ZG24F
OFF
ON
OFF
4. ZG24F
ON
ON
OFF
5. ZG24F
OFF
OFF
ON
KW-Nr. 1100060
On the last ZG24F module in the chain, the Dipp-4 switch is set to ON and serves as termina-
tion of the line.
On each ZG24F, there are 2 34-
pin flat connectors to which an EIT module can be connected.
This allows the call lines to be connected to the internal control at 64 stops.
Activation takes place:
1.) Insert the module on the FKR computer
2.) By activating in the B21 menu:
Three settings are selectable:
A. Without FKR + EIT
B. With FKR + EIT (IC .. IE) -> Standard without ZG24F
C. With FKR + EIT (IC .. IU) -> With ZG24F Expansion Units!
Terminal -Description Expansion Unit DAVID-ZG-24F
Emergency Power+24V
240
34P Flatwire To EIT
Emergency Light
242
Alert
243
Intercom Wire
605
34P Flatwire To EIT
Intercom Wire
604
Intercom Wire
603
Intercom Wire
602
3
on
Voltage +24V DC
200
2
GND / 0V
500
1
0
DIPP-SWITCH
10P Flatwire To FKR
DAVID-ZG-24F
Expansion Unit

Table of Contents