B608- ENERGY SAVING
PARAMETER: CAR LIGHT AUTOMATIC OFF
Car light can be off if car stands at rest in the stop place without calls or the car is in park stop.
This can be deactivated in the parameter automatic off.
PARAMETER: CARLIGHT DELAY
In order to avoid unnecessary in and turn-off processes of the car light one time interval should be
selected in the parameter which it can be proceeded that no more calls are present. One time interval
is adjustable from 0 to 6500 seconds. Default value is 60 seconds.
PARAMETER: CAR INDICATOR AUTOMATIC OFF
Car indicater can be off if car stands at rest in the stop place without calls or the car is in park stop.
This can be deactivated in the parameter automatic off.
PARAMETER: CAR INDICATER DELAY
Time interval from 0 to 6500 seconds is adjusable. As default value is 120 seconds selected.
PARAMETER: FLOOR INDICATER AUTOMATIC OFF
Floor indicater can be off if car stands at rest in the stop place without calls or the car is in park stop.
This can be deactivated in the parameter automatic off.
PARAMETER: FLOOR INDICATER DELAY
Time interval from 0 to 6500 seconds is adjusable. As default value is 300 seconds selected.
PARAMETER: FREQUENCY INVERTER STANDBY
Frequency inverter can be in standby modus if the car stands inoperative in stop place.
The electronics boards are shifted into sleep modus and intermediate circuit are unloaded.
This can be activated in the parameter Automatic off.
PARAMETER: FREQUENCY INVERTER STANDBY DELAY
Time interval from 0 to 6500 seconds is adjusable. As default value is 600 seconds selected.
PARAMETER: FREQUENCY INVERTER SWICH OFF
To the standby mode the frequency inverter becomes additionally completely without tension. The pro-
cedure is introduced over the elevator bus. This can be deactivated in the paramenter automatic off.
PARAMETER: FREQUENCY INVERTER SWITCH OFF DELAY
Time interval from 0 to 6500 seconds is adjustable. As default value is 900 seconds selected.
PARAMETER: DOOR DRIVE TRAIN AUTOMATIC OFF
Door Drive Train can be off if car stands at rest in the stop place without calls or the car is in park stop.
This can be deactivated in the parameter automatic off.
PARAMETER: DOOR DRIVE TRAIN DELAY
Time interval from 0 to 6500 seconds is adjustable. As default value is 60 seconds selected.
PARAMETER: MODUS S1
Operation mode S1( sleep mode ) is here activatable for the processor system.
PARAMETER: MODUS S2
Operation mode S2( deep sleep mode) is here activatable for the processor system.