KW Aufzugstechnik GmbH OPERATING MANUAL DAVID-613
DAVID-D613-V125-E 13.04.2021 Page - 175 -
A572 Reversiercontakt Door-3
Penthouse -No.1 Calling for visitor (Indication)
A575-Penthouse-1 Residents
Penthouse -No.1 Calling for Residents (Indication)
Penthouse -No.2 Calling for visitor (Indication)
A577-Penthouse-2 Residents
Penthouse -No.2 Calling for Residents (Indication)
Penthouse -No.3 Calling for visitor (Indication)
A579-Penthouse-3 Residents
Penthouse -No.3 Calling for Residents (Indication)
Penthouse -No.4 Calling for visitor (Indication)
A581-Penthouse-4 Residents
Penthouse -No.4 Calling for Residents (Indication)
Penthouse -No.5 Calling for visitor (Indication)
A583-Penthouse-5 Residents
Penthouse -No.5 Calling for Residents (Indication)
Penthouse -No.6 Calling for visitor (Indication)
A585-Penthouse-6 Residents
Penthouse -No.6 Calling for Residents (Indication)
Penthouse -No.7 Calling for visitor (Indication)
A587-Penthouse-7 Residents
Penthouse -No.7 Calling for Residents (Indication)
Penthouse -No.8 Calling for visitor (Indication)
A589-Penthouse-8 Residents
Penthouse -No.8 Calling for Residents (Indication)
Active, if externally called & turning door or light barrier
Indication, if Controller & Light OFF
A592 Portallight Floor 01
Active when lift enters Fl. 01 or door open in Fl.01
A593 Portallight Floor HS02
Active when lift enters Fl. 02 or door open in Fl.02
A594 Portallight Floor HS03
Active when lift enters Fl. 03 or door open in Fl.03
A595 Portallight Floor HS04
Active when lift enters Fl. 04 or door open in Fl.04
A596 Portallight Floor HS05
Active when lift enters Fl. 05 or door open in Fl.05
A597 Portallight Floor HS06
Active when lift enters Fl. 06 or door open in Fl.06
A598 Portallight Floor HS07
Active when lift enters Fl. 07 or door open in Fl.07
A599 Portallight Floor HS08
Active when lift enters Fl. 08 or door open in Fl.08
A600 Portallight Floor HS09
Active when lift enters Fl. 09 or door open in Fl.09
A601 Portallight Floor HS10
Active when lift enters Fl. 10 or door open in Fl.10
A602 Portallight Floor HS11
Active when lift enters Fl. 11 or door open in Fl.11
A603 Portallight Floor HS12
Active when lift enters Fl. 12 or door open in Fl.12
A604 Portallight Floor HS13
Active when lift enters Fl. 13 or door open in Fl.13
A605 Portallight Floor HS14
Active when lift enters Fl. 14 or door open in Fl.14
A606 Portallight Floor HS15
Active when lift enters Fl. 15 or door open in Fl.15
A607 Portallight Floor HS16
Active when lift enters Fl. 16 or door open in Fl.16
Is active when door-1 opens, door command door-1-up is delayed for 1 sec
Is active when door-2 opens, door command door-2-up is delayed for 1 sec
Is active when door-3 opens, door command door-3-up is delayed for 1 sec
A611 Reset Safe Shaftcopy
Function high, then the powersupply is OFF
Function high, then endswitch is open or open without endswitch
Function high, then endswitch is open or open without endswitch
Function high, then endswitch is open or open without endswitch
Function high, then endswitch is closed or closed without endswitch
Function high, then endswitch is closed or closed without endswitch
Function high, then endswitch is closed or closed without endswitch
Puls for 2 Sec for Speech-Output
Puls for 2 Sec for Speech-Output
A620 Pushbuttoon Door Open-afer
Drive Down
Signal is ON, until the door is closed
„1“ if interior call pressed but floor lock in this floor
Active if there is an error
A624 Shaft smoke extraction active
If „1“ then is the shafts smoke extraction active
A625 Transport of dangerous goods
If “1” the dangerous goods transport is active
A626 Reset GB preschutdown
For GB with pre-shutdown contact, these can be set with the output Be re-
set
A627-Penthaus-9 calling visitors
A628 Penthaus-9 calling Penthouse
A629-Penthaus-10 calling visitors
A630 Penthaus-10 calling Pent-
house
A631 Traffic Light Red Car Protec-
tionroom
Switching the Traffic Light red for Car Protectionroom
A631 Traffic Light Green Car Protec-
tionroom
Switching the Traffic Light green for Car Protectionroom
Outputfunction is active, if the shaft light is ON