3-58
Maintenance > Parts Replacement
7
Replace the label (squared in red) that comes with the new
decurler unit according to the region of use, if necessary.
8
Attach the new unit in the reverse step of removing the decurl
unit.
9
[Home] key > [...] > [Professional Settings] > [U251 Clear
Maintenance Counter].
10
Select [05 Decurl] > [Start] key.
The counter for replaced part is cleared.
Check the status after replacement
Make a test print and check that there are no paper jams, double feed or no feed. If there is any problem, try again from
step 1.