LACO ORIGINAL OPERATING INSTRUCTIONS TITANTEST
71
© 2018 LACO TECHNOLOGIES, INC. - [TitanTest itna01en1-07 BA.fm] - 1807
16. Insert the mains plug again.
17. Dispose of old oil as stipulated by local regulations.
8.4.4 Oil mist filter (M-Series only)
Maintenance work for devices with oil-sealed fore pump UNO 006A:
TITANTEST™ TW Series
8.4.4.1 Check and empty the oil mist filter and clean the oil pan (M-
Series only)
You may combine the work steps described here with refilling or changing
oil for the UNO 006 A (see Chapter 8.4.3.2: "Replenish the oil (M-Series only)",
page 69 or see Chapter 8.4.3.3: "Change the oil (M-Series only)", page 70).
1. Switch the device off at the mains plug.
2. Pull out the mains plug.
3. Loosen the cover on the left and right side using an 8 mm Allen wrench
(
see Chapter 8.4.2: "Removing the cover (M-Series only)", page 69).
4. Lift off the cover.
5. Loosen the grounding cable.
6. Perform a visual inspection of the transparent plastic cylinder.
7. If there is oil in the plastic cylinder, unscrew the plastic cylinder by hand
in a counter-clockwise motion. Dispose of the collected oil as stipulated
by local regulations.
8. Screw the plastic cylinder back in.
9. Clean the oil pan with a lightly alcohol-soaked cloth.
10. Connect the grounding cable.
11. Replace the cover and secure it with an 8 mm Allen wrench on the left
and right side.
12. Insert the mains plug again.

Table of Contents