10: Maintenance and Diagnostics Settings
PremierWave® XN Intelligent Gateway User Guide 102
System Settings
The PremierWave XN intelligent gateway system settings allow for rebooting the device, restoring
factory defaults, uploading new firmware and updating a system’s short and long name.
Note: Anytime you reboot the unit, this operation will take some time to complete.
Please wait a minimum of 10-20 seconds after rebooting the unit before attempting to
make any subsequent connections.
Table 10-12 System Settings
To Reboot or Restore Factory Defaults
Using Web Manager
To access the area with options to reboot, restore to factory defaults, upload new firmware,
update the system name (long or short names) or to view the current configuration, click
System in the menu.
Using the CLI
To enter the command level: enable
Using XML
Include in your file: <configgroup name=”xml import control”>
System Settings Description
Reboot Schedule Set the reboot schedule by enabling the State, and setting the Schedule to a
specific daily set Time (24 hour) or specific hour, day or weekly Interval.
Reboot Device
Click the Reboot button to reboot the device.
Restore Factory Defaults
Click Factory Defaults to restore the device to the original factory settings. All
configuration will be lost. The PremierWave unit automatically reboots upon
setting back to the defaults.
Upload New Firmware
FTP to the PremierWave device. Write the new firmware file to firmware.rom
on the PremierWave unit by clicking Choose File to browse to the new
firmware file, and click Upload button to upload the chosen file to the system.
The device automatically reboots upon the installation of new firmware. See
the section, FTP Settings on page 128.
Short Name Enter a short name for the system name. A maximum of 32 characters are
allowed.
Long Name Enter a long name for the system name. A maximum of 64 characters are
allowed.

Table of Contents

Other manuals for Lantronix PremierWave XN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix PremierWave XN and is the answer not in the manual?

Lantronix PremierWave XN Specifications

General IconGeneral
BrandLantronix
ModelPremierWave XN
CategoryServer
LanguageEnglish

Related product manuals