Fig. 13-4 
Fig.  13-5  shows  the  normal  secondary  (the  upper  one)  and  (the  lower  one) 
primary ignition waveform of direct ignition system. Beause the on/off of primary 
circuit  is  not  opening/closing  of  mechanical  contact,  but  the  conduction  of 
transistor. The primary voltage  has no obvious oscillations within the duration, 
but  the  voltage  increases  during  the  magnetization  process  due  to  current 
limiting,  and  this  change  can  cause  corresponding  fluctuations  of  secondary 
voltage line as a result of induction of ignition coil.