  When checking if there is a short in the line, please disconnect the CEU and 
the relevant sensor, then measure the resistance value of the ports between 
the connected port and the vehicle body. If the resistance value is more than 
1MΩ, no fault occurs. 
  Before disassembling the engine electrical control system cable, cut off the 
power supply, that is, turn the ignition switch OFF and disconnect the cables 
on the battery poles.   
  Contact the test probe and the two terminals/ the two leads to be measured 
when measuring the voltage between the two terminals or the two leads. 
  Contact the red test probe to the terminal/ the cable to be measured, and the 
black  probe  to  the  ground  when  measuring  voltage  of  one  terminal/  one 
cable. 
  When  checking  the  continuity  of  the  terminals,  contacts  and  leads,  the 
method for measuring their resistances can be used. 
  Check the faults in the terminals of the CEU to sensors, relays, etc. 
  There are two test probes in the testing wire. The black one is the common 
signal terminal  (signal  GND);  the red  one  is  the  input  terminal  for  voltage, 
resistance,  and  frequency  test  and  output  terminal  for  simulation  voltage, 
simulation frequency and oxygen sensor. Please choose the correct probes 
to match the different terminals.